  • Single-phase bridge schematic showing current through D1 and D4 in one AC input half-cycle and through D2 and D3 in the other. Load current flows from DC+ to DC− in both half-cycles.

    IMD and SMD Bridge Rectifier Replacement: Verifying Thermal Performance and Inrush Current

    What to Recheck When Swapping IMD and SMD Bridge Rectifiers

    When replacing a bridge rectifier in a single-phase offline SMPS, first check the board and cooling conditions specified alongside the current rating. The maximum average rectified output current and reverse voltage ratings are the starting point, but a package change also calls for rechecking the heat dissipation path on the new board, the startup waveform, and the insulation arrangement. For guidance on selecting the basic ratings, see How to Select Basic Current and Reverse Voltage Ratings for Bridge Diodes.

    Here, IMD refers to through-hole (THT) mounting, where leads are inserted into PCB holes, and SMD refers to surface mounting, where the device is soldered to lands on the PCB surface. The figure below redraws the single-phase full-wave bridge from the Vishay GBU4A–GBU4M datasheet, p. 1 to highlight the terminal connections. The two cathodes meet at DC+, and the two anodes meet at DC−.

    Single-phase bridge schematic showing current through D1 and D4 in one AC input half-cycle and through D2 and D3 in the other. Load current flows from DC+ to DC− in both half-cycles.
    When the bridge conducts, D1 and D4 conduct if the AC1 voltage is higher, and D2 and D3 conduct if the AC2 voltage is higher. In both cases, load current flows from DC+ to DC−.

    When the bridge conducts during the half-cycle in which AC1 is higher than AC2, current flows from AC1 through D1 to DC+. After passing through the load, it returns from DC− through D4 to AC2. When the bridge conducts during the opposite half-cycle, current flows from AC2 through D2 to DC+ and, after passing through the load, returns from DC− through D3 to AC1. The conducting diodes change each half-cycle, but the direction of current through the load stays the same. The terminal labels in the figure indicate circuit connections. Check the candidate part’s pinout diagram for the actual pin numbers and its recommended footprint for the PCB lands.

    Mounting Differences Between THT and SMD

    Comparison Item Through-Hole (THT) Surface Mount (SMD) What to Check When Replacing
    Mounting and soldering Insert the leads into drilled holes and evaluate processes such as wave, selective, or hand soldering. Place the part on surface lands and evaluate the solder paste and reflow conditions. Manufacturer-recommended hole or land dimensions and soldering conditions
    Height and mechanical interference Check the body height and leads protruding below the PCB. Check the body height and spacing to nearby components and covers. Interference on both sides of the board, including assembly tolerances
    Primary heat dissipation path Depending on the part number, heat dissipates through the leads and PCB, the package surface, or a heatsink attached to the case. Check paths such as those from the terminals and lands into the PCB copper and thermal vias. The heat dissipation path in the new mounting arrangement and how to replace the existing cooling structure
    Continuous current rating Some ratings are specified at a case temperature or at an ambient temperature on a particular PCB. Even for the same part number, the rating can vary with the test board and pad conditions. Temperature reference point, board and cooling conditions, load, and derating curve
    Inrush current rating Check IFSM and the pulse test conditions for the specific part number. Check IFSM and the pulse test conditions for the specific part number. Actual peak, pulse width and shape, initial temperature, and repeated startup conditions
    Terminal layout and insulation distances Check the pin order, copper around the holes, protruding leads, and nearby metal. Check the terminal order, paths between lands, and paths along the package surface. Minimum clearance and creepage distances with the new footprint and in the assembled configuration

    Read Current Ratings Alongside Temperature and Mounting Conditions

    The maximum average rectified output current applies under the specified mounting and temperature conditions. The GBU4A–GBU4M and MB6S are not candidates for replacing one another; they are separate examples that show which conditions to look for in a ratings table. TC is the case temperature, and TA is the ambient temperature.

    • Through-hole GBU4A–GBU4M: The maximum average rectified output current of 4.0 A applies when the case is mounted on a 40 × 40 × 1.5 mm aluminum heatsink and held at TC = 100 °C. For PCB mounting in free air without a heatsink, using 12 × 12 mm copper pads and a 9.5 mm lead length, the rating at TA = 40 °C is 3.0 A. In Vishay 88614, p. 1 and p. 2, Fig. 1, the PCB curve applies to a 60 Hz resistive or inductive load. When calculating conduction loss for a bulk-capacitor input stage, consider both the average rectified output current and the RMS current in the bridge branch.
    • Surface-mount MB6S: At the ratings table’s default condition of TA = 25 °C, the maximum average rectified output current is 0.5 A on a glass-epoxy PCB with 1.3 × 1.3 mm pads, and 0.8 A on a 20 × 20 mm aluminum substrate with pads of the same dimensions. The pad dimensions are the same; the substrates differ. 20 × 20 mm is the size of the test board. See the maximum ratings table and notes in Vishay 88661, p. 1 for the mounting conditions behind both values.

    Calculating Conduction Loss from Bridge Branch Current

    To calculate loss, first identify which branch carries the current. Given the input active power Pin, the RMS line voltage Vline,rms, and the total power factor PF, the RMS line current can be calculated as Iline,rms = Pin / (Vline,rms · PF). However, if current splits into other paths, such as through the EMI filter’s X capacitor, the line current differs from the bridge branch current. For bridge conduction loss, use the branch current iB(t) entering the bridge’s AC terminals.

    Averaging the absolute value of iB over a complete cycle of the normal operating waveform gives the average rectified output current, Irect,avg = 평균(|iB|). The RMS bridge branch current is IB,rms = RMS(iB). For a capacitor-input circuit without PFC, if the steady-state bus voltage ripple is small, the average power drawn by the bus load and the average bus voltage give Irect,avg ≈ Pbus / Vbus,avg. With boost PFC, calculate the average from the bridge branch waveform rather than putting the power and voltage of the bus downstream of the boost stage into this equation. Check the RMS current in the bulk capacitor branch and the capacitor’s permissible ripple current separately.

    Assume all four diodes have the same characteristics and approximate the forward voltage as VF(i) ≈ VF0 + rd · i. VF0 is the voltage intercept in this equation, and rd is the slope of forward voltage versus current. Since the same current flows through two diodes during conduction, the average conduction loss for the entire bridge is:

    PD ≈ 2(VF0 · Irect,avg + rd · IB,rms²)

    Conduction loss is 0 during intervals when no current flows. The term to focus on is the second one. For the same diode model with rd > 0, a higher RMS bridge branch current increases this term even if the average current is unchanged. Determine VF0 and rd for each candidate part from its forward characteristics over the actual current and temperature range.

    Two normalized pulses with an average of 1. With conduction over 50% of the cycle, the RMS value is 1.41; at 20%, it is 2.24.
    These ideal rectangular pulses are normalized to the same average current. Reducing the conduction interval from 50% to 20% increases the RMS current from 1.41 to 2.24. For the same diode model, the loss term proportional to the square of the RMS current becomes 2.5 times as large.

    The Thermal Path Changes Junction Temperature Even at the Same Loss

    If the board, cooling environment, and basis for power dissipation match the conditions under which the thermal resistance is defined, use TJ ≈ TA + PD · RθJA for a 1-order estimate of the steady-state junction temperature. When using case temperature, follow the manufacturer’s specified measurement location and thermal model. If a thermal metric is defined on a per-die basis, use the loss per die rather than the total bridge loss.

    When heat flow through the heatsink dominates and the metrics are defined on a consistent basis, RθJC + RθCS + RθSA can be used as a 1-order approximation. These are the junction-to-case, case-to-heatsink, and heatsink-to-ambient thermal resistances, respectively. See TI’s Semiconductor and IC Package Thermal Metrics, §1–2 for definitions and conditions of use.

    Worked example. With Irect,avg = 0.8 A, IB,rms = 1.5 A, VF0 = 0.75 V, and rd = 0.020 Ω, the conduction loss is 2 × (0.75 × 0.8 + 0.020 × 1.5²) = 1.29 W. Include only this conduction loss in the thermal calculation. Hold the local ambient temperature at TA = 55 °C and vary only the board’s heat dissipation conditions.

    • Assuming RθJA = 30 K/W: TJ ≈ 55 + 1.29 × 30 = 93.7 °C
    • Assuming RθJA = 50 K/W: TJ ≈ 55 + 1.29 × 50 = 119.5 °C
    Graph comparing junction temperatures for two assumed thermal resistances at an ambient temperature of 55°C. At a loss of 1.29 W, the temperatures are 93.7°C and 119.5°C.
    At an ambient temperature of 55°C, the assumed board thermal resistances are 30 K/W and 50 K/W. With a bridge loss of 1.29 W, the estimated junction temperatures are 93.7°C and 119.5°C, respectively.

    In this example, the thermal path, not the loss, accounts for the difference in junction temperature. The two thermal resistances are assumed values used to illustrate that difference; they do not correspond to any specific part number or mounting method. For an actual replacement, calculate the loss for each candidate and compare the junction temperature estimated for the new board conditions with the maximum junction temperature in that candidate’s datasheet.

    Assess Startup Inrush and External Surge Separately

    Startup inrush is the current that flows while the bulk capacitor charges. Establish the inrush conditions by combining the maximum input voltage and switch-on phase angle, the bulk capacitor’s capacitance tolerance and residual voltage, and the source impedance. If the circuit uses an NTC, check not only cold startup but also reapplication of power while the NTC is still hot and the interval between repeated starts. From the current waveform through the diode in question, determine the peak Ipk, pulse width and shape, and ∫i²dt. Compare these, together with the initial junction temperature immediately before the pulse, with the test conditions in the candidate’s datasheet.

    The maximum ratings table in the Vishay MB6S datasheet, p. 1 uses TA = 25 °C as the default condition unless otherwise specified. IFSM 35 A is the non-repetitive peak forward surge current for a single 8.3 ms half-sine wave superimposed on the rated load. Fusing I²t of 5.0 A²·s is a separate rating that applies for t < 8.3 ms. Even if the startup peak is below 35 A, a longer or repeated pulse differs from the test conditions. If the actual waveform or repetition conditions differ, check for a manufacturer rating or a verification method applicable to those conditions.

    For an external surge, check the reverse voltage across the diode after the surge has passed through the protection circuit. IEC 61000-4-5 specifies a method for testing equipment immunity to external transient surges. Check the actual reverse voltage in the test modes and polarities applicable to the product, accounting for the clamping voltage tolerance of the protective device and the parasitics of the wiring and PCB.

    Compare the recurring peak reverse voltage during normal operation with the candidate’s maximum repetitive peak reverse voltage, VRRM. The VRRM in the MB6S datasheet, p. 1 is 600 V.

    Check Insulation Distances Along the Shortest Paths in the Assembly

    When changing the footprint, check not only the spacing between pads but also the package surface, leads protruding below the PCB, the heatsink, and nearby metal. With all of these included in the assembled configuration, recheck the shortest clearance and creepage paths.

    Distance requirements are determined by the safety standard and edition applicable to the product and its target market. IEC 62368-1 is an example of a safety standard for AV and ICT equipment within its scope. Check the shortest paths in the assembled configuration against the applicable standard, taking into account voltage conditions, overvoltage category, pollution degree, material group, altitude, and other relevant factors. Connect heat-dissipating copper and thermal vias to the same electrical net, and maintain the required insulation spacing after adding them.

    Pre-Replacement Checklist

    • [ ] THT → SMD: Check the recommended lands and reflow conditions. Establish a heat dissipation path from the lands to copper and thermal vias on the same net. Check the insulation spacing between lands and terminals, and verify that the required spacing remains after enlarging the copper areas. If removing the existing heatsink, reassess junction temperature with a thermal model that matches the new board and mounting conditions.
    • [ ] SMD → THT: Match the two AC terminals and the DC polarity to the actual pin order, and check the hole dimensions and soldering process. Check for mechanical interference and verify the spacing to nearby metal, accounting for the body height and lead protrusion below the PCB. If using a heatsink, also check the attachment arrangement, thermal interface, and required electrical insulation.
    • [ ] Ratings and pinout: Verify the full part numbers and pinouts of the existing and candidate parts. Read the allowable average rectified current for the conditions of use from the candidate’s derating curve, and compare the repetitive peak reverse voltage during normal operation with VRRM.
    • [ ] Thermal: Find the worst-case thermal operating point across the input and load ranges, including low input at maximum load and high-temperature conditions. Once the actual board and mechanical assembly reach thermal equilibrium, assess junction temperature using an applicable thermal model.
    • [ ] Inrush and surge: Verify inrush at high-input startup and when reapplying power under cold and hot conditions. Test external surge immunity separately.
    • [ ] Insulation and EMI: Recheck the insulation requirements of the applicable safety standard and conducted EMI on the new PCB and in the assembled configuration.

    When checking a rectifier stage connected directly to the AC mains, use appropriately rated isolated or differential measurement equipment. After disconnecting power, check the residual voltage on the bulk capacitor and handle the circuit only after the capacitor has been safely discharged.

    Even when the numbers in the ratings table match, the replacement decision depends on whether the candidate part meets the thermal, inrush, insulation, and EMC requirements on the actual board.