Table of Contents
Evaluating a 10 µH Replacement: Can You Swap Parts with the Same Inductance?
This hypothetical design example evaluates a TI TPS54308 buck converter with a maximum input of 28 V, an output of 5 V at 3 A, and a nominal switching frequency of 350 kHz. Can the SRN6045-100M, also rated at 10 µH and in the same 6 mm size class, be ordered in place of the original 10 µH output inductor (SRP6060FA-100M)?
Following the article on choosing an MLCC replacement for a 5 V buck output, this article looks at output inductor L1. The conclusion up front: Do not order the SRN6045-100M as a replacement in this design. Both parts are specified at 10 µH ±20%, but when the initial −20% tolerance is included in the calculations, the candidate falls short of both the normal peak current (\(I_{\text{sat}}\)) and the RMS current (\(I_{\text{rms}}\)) requirements. The Isat vs. normal peak current and Irms vs. normal RMS current rows in the table below show the difference.
| Comparison item | Calculated design value or evaluation criterion | Original: SRP6060FA-100M | Candidate: SRN6045-100M |
|---|---|---|---|
| Nominal L and initial tolerance | At −20%: 8 µH | 10 µH ±20% | 10 µH ±20% |
| Isat vs. normal peak current | 3.733 A; Isat is the current at which L drops by 30% | 7.6 A typical | 3.0 A — falls short |
| Irms vs. normal RMS current | 3.030 A; compare both parts at a 40 °C temperature rise | 5.0 A typical (20 °C rise), 7.0 A typical (40 °C rise) | 2.5 A (40 °C rise) — falls short |
| Isat vs. high-side current-limit threshold | Check normal peak current margin at the 4.0 A minimum and effective L near the 5.9 A maximum | Typical Isat of 7.6 A is above 5.9 A | Isat of 3.0 A is below 4.0 A |
| DCR and winding conduction loss | Calculated using maximum DCR at 25 °C and the same RMS current of 3.030 A | 26.6 mΩ typical / 29.3 mΩ maximum → approximately 0.269 W | 58.6 mΩ maximum → approximately 0.538 W |
| Core, shielding, and dimensions | Check the recommended land pattern and assembly height separately | Metal alloy powder core, flat copper wire, shielded; 6.6 × 6.4 × 5.8 mm (each ±0.2 mm) | Ferrite core, semi-shielded; plan dimensions 6.0 × 6.0 mm (each ±0.2 mm), height 4.5 mm max |
| Ordering decision | Check normal peak and RMS currents first | Passes the stage 1 comparison based on typical datasheet values | Rejected as a direct replacement in the 3 A design |
Seeing that the candidate’s \(I_{\text{sat}}\) is 3.0 A, it is easy to think, “The load is 3 A, so might it just work?” But saturation current must be compared with the peak current, including ripple, not the average load current. Moreover, for both parts, \(I_{\text{sat}}\) marks the point at which inductance has already dropped by 30%. Heating must be checked separately by comparing RMS current, not peak current, with \(I_{\text{rms}}\). The SRN6045-100M fails both checks.
Calculation basis and references. The calculations below use a triangular-wave approximation for 28 V to 5 V at 3 A and 350 kHz, with inductance at its −20% tolerance limit (8 µH). Converter operation and equations follow the TI TPS54308 datasheet (SLUSCV2B Rev. B), p. 1 (350 kHz FCCM and peak current mode), p. 5 §5.5 (current limit and frequency range), and pp. 15–16 §7.2.3.6.1 (Eq. 8–10). The inductor specifications, based on 25 °C, 100 kHz, and 1 V, come from p. 1 of the two Bourns datasheets.
The table below reproduces the respective 100M rows and general specification notes from the original Electrical Specifications @ 25 °C tables in Bourns SRP6060FA Rev. 06/24 p. 1 and SRN6045 Rev. 01/20 p. 1.
| Part number (Bourns) | L (@ 100 kHz / 1 V) | SRF Typ. | DCR | Irms | Isat (30% drop in L) | Operating temperature (including temperature rise) |
|---|---|---|---|---|---|---|
| SRP6060FA-100M | 10.0 µH ±20% | 12 MHz | 26.6 mΩ typ / 29.3 mΩ max | 5.0 A (20 °C) / 7.0 A (40 °C) typ | 7.6 A typ | −55~+155 °C |
| SRN6045-100M | 10 µH ±20% | 15 MHz | 58.6 mΩ max (0.0586 Ω) | 2.5 A (40 °C) | 3.0 A | −40~+125 °C |
Replacement Location: L1 Between SW and VOUT
The part to replace is output inductor L1, located between the SW (2) pin and VOUT. When the high-side MOSFET turns on, current flows from VIN (3) → high-side MOSFET → SW (2) → L1 → load and returns to the input. When the low-side MOSFET turns on, current returning from the load enters GND (1) and flows through the low-side MOSFET up to SW (2). In both intervals, current flows in the same direction through L1 and the load downstream of SW (2). The HS Current Sense label at the top of the figure illustrates the principle of peak current control; it does not represent actual wiring.

Figure: A functional equivalent based on the external power stage in TI Rev. B p. 13 Figure 7-1 (L1 10 µH, C1 10 µF, C2 0.1 µF, C4 and C5 each 22 µF, C3 0.1 µF), incorporating the description of operation on p. 1 and the high-side current limit on p. 5 §5.5. C3 is between BOOT (6) and SW (2). Only the functional relationships are shown for high-side current sensing and the SW-referenced drive supply. The external FB and EN setting networks, detailed charging, drive, and protection circuitry, dead time, and reverse current are omitted. The 5 V label denotes a condition from a separate calculation example.
Recalculating Ripple, Peak, and RMS Current Using Eq. 8–10
The principle behind current continuity is covered in Coil and Inductor Basics. Here, start by setting the allowable ripple. As in the example for TI Eq. 8, if the ripple ratio \(K_{\text{IND}}\) is set to 30%, the target ripple at 3 A is \(3\,\text{A} \times 30 / 100 = 0.90\,\text{A}_{\text{p-p}}\). 30% is the example design target used in this calculation.
The original minimum-inductance equation from the TI TPS54308 datasheet (SLUSCV2B), p. 15 §7.2.3.6.1 (Eq. 8), is shown below.
\[L_{\text{MIN}} = \frac{V_{\text{OUT}} \times (V_{\text{IN(MAX)}} – V_{\text{OUT}})}{V_{\text{IN(MAX)}} \times K_{\text{IND}} \times I_{\text{OUT}} \times f_{\text{sw}}} \quad \text{(TI Eq. 8)}\]
With a 28 V input, a nominal frequency of 350 kHz, and a 3 A load, setting the ripple target to 30% (0.90 A p-p) requires 9.24 µH at a 3.3 V output and 13.04 µH at a 5 V output. To meet this target at 5 V and 3 A, the nominal inductance must be at least \(13.04\,\mu\text{H} / 0.8 \approx 16.30\,\mu\text{H}\) even when accounting only for the nominal 350 kHz frequency and the initial −20% tolerance. Applying the same tolerance to a nominal 15 µH gives a lower limit of 12 µH, which falls short of the required 13.04 µH.
To compare the two parts at 5 V, hold the nominal inductance at 10 µH and calculate ripple using \(\Delta I_L = \frac{V_{\text{OUT}} \times (V_{\text{IN}} – V_{\text{OUT}})}{V_{\text{IN}} \times L \times f_{\text{SW}}}\).
| 28 V→5 V·3 A, 350 kHz | L used in the equation | Calculated ripple | Relative to 3 A |
|---|---|---|---|
| Nominal | 10 µH | 1.173 A p-p | 39.1% |
| Initial −20% | 8 µH | 1.467 A p-p | 48.9% |
Next, on p. 16 of the TI datasheet, Eq. 9 and Eq. 10 directly incorporate the −20% inductance tolerance (a factor of 0.8, shown as \(1.6 = 2 \times 0.8\) in the denominator of the peak-current equation) to calculate the worst-case RMS and peak currents.
\[I_{L(\text{RMS})} = \sqrt{I_{\text{OUT(MAX)}}^2 + \frac{1}{12} \left( \frac{V_{\text{OUT}} \times (V_{\text{IN(MAX)}} – V_{\text{OUT}})}{V_{\text{IN(MAX)}} \times L_O \times f_{\text{SW}} \times 0.8} \right)^2} \quad \text{(TI Eq. 9)}\]
\[I_{L(\text{PK})} = I_{\text{OUT(MAX)}} + \frac{V_{\text{OUT}} \times (V_{\text{IN(MAX)}} – V_{\text{OUT}})}{1.6 \times V_{\text{IN(MAX)}} \times L_O \times f_{\text{SW}}} \quad \text{(TI Eq. 10)}\]
Substituting the unrounded ripple calculated at the lower tolerance limit into Eq. 10 and Eq. 9 gives \(I_{\text{PK}} = I_{\text{OUT}} + \frac{\Delta I_L}{2} \approx 3.733\,\text{A}\) and \(I_{\text{RMS}} = \sqrt{I_{\text{OUT}}^2 + \frac{\Delta I_L^2}{12}} \approx 3.030\,\text{A}\). Since the lower tolerance limit of 8 µH was used directly in the equations, do not multiply by 0.8 again. The calculations so far account only for the initial tolerance. Check the component data for effective L at the actual bias current and temperature. If 30% ripple is mandatory, I would revisit the nominal inductance before looking for another 10 µH candidate.
Normal Peak Current Margin up to 4.0 A and Effective L Near 5.9 A
The high-side current-limit row in TI p. 5 §5.5 Electrical Characteristics gives 4.0 A minimum, 5.0 A typical, and 5.9 A maximum at a junction temperature of \(T_J = -40 \sim +125\,^\circ\text{C}\). In the OSCILLATOR section of the same table, the center switching frequency \(F_{\text{sw}}\) is 255 kHz minimum, 350 kHz typical, and 445 kHz maximum. Unless otherwise specified, the table’s common test conditions, \(T_J = -40 \sim +125\,^\circ\text{C}\) and \(V_{\text{IN}} = 4.5 \sim 28\,\text{V}\), apply to this frequency row.
The table below reproduces the current-limit and oscillator-frequency rows from TI TPS54308 SLUSCV2B p. 5 §5.5 Electrical Characteristics (common conditions: \(T_J = -40 \sim +125\,^\circ\text{C}\) and \(V_{\text{IN}} = 4.5 \sim 28\,\text{V}\), unless otherwise specified).
| Parameter | Item (test conditions) | MIN | TYP | MAX | Unit |
|---|---|---|---|---|---|
| \(I_{\text{LIM\_HS}}\) | High side current limit (Maximum inductor peak current) | 4 | 5 | 5.9 | A |
| \(I_{\text{LIM\_LS}}\) | Low side source current limit (Maximum inductor valley current) | 3.1 | 4 | 5.5 | A |
| \(F_{\text{sw}}\) | Center switching frequency | 255 | 350 | 445 | kHz |
At the normal 3 A load, check peak current margin against the minimum current limit of 4.0 A. At 350 kHz and 8 µH, the calculated peak is 3.733 A. For 28 V to 5 V at 3 A, keep the initial −20% tolerance value of L=8 µH and lower only the frequency to 255 kHz. With a constant-L approximation and no current-limit intervention, Eq. 10 gives the following result.
\[I_{\text{PK}} = 3\,\text{A} + \frac{5\,\text{V} \times (28\,\text{V} – 5\,\text{V})}{2 \times 28\,\text{V} \times 8\,\mu\text{H} \times 255\,\text{kHz}} \approx 4.007\,\text{A}\]
Under these conditions, ripple is 2.013 A p-p and RMS current is 3.056 A. The calculated peak is about 7 mA above the minimum current-limit threshold, so there is no calculated margin under these conditions even with the original part.
When current surges, as in an overload or short circuit, what matters is how much inductance remains near the maximum current-limit threshold of 5.9 A. The original part’s typical \(I_{\text{sat}}\) (7.6 A) leaves margin above 5.9 A, but a single number in the table does not show how steeply inductance falls with current. Before making the final selection, read the remaining inductance near 5.9 A directly from the DC bias curve, and verify startup, load transient, and short-circuit waveforms on the board.
DCR Loss and How to Evaluate the Next Candidate
Using the maximum DCR at 25 °C and the same calculated RMS current (3.030 A) to calculate winding conduction loss (\(P_{\text{DCR}} = I_{\text{RMS}}^2 \times \text{DCR}\)) shows a clear difference. The original part gives \(3.030^2 \times 0.0293\,\Omega \approx 0.269\,\text{W}\) and the candidate gives \(3.030^2 \times 0.0586\,\Omega \approx 0.538\,\text{W}\), so the candidate’s copper loss is exactly double (about 0.269 W higher). In actual operation, DCR increases as the temperature rises, and AC winding and core losses add to the total, widening the difference in heating.
In what order should you check another replacement candidate? Start with the allowable ripple and the effective inductance at the actual operating point. Read the remaining inductance from the candidate’s DC bias curve at the normal peak current (at 350 kHz: 3.733 A) and at the maximum current limit (5.9 A). Then use that effective inductance at the minimum switching frequency (255 kHz) to recalculate ripple and peak current. Check that there is still margin against both the allowable ripple and the minimum current-limit threshold (4.0 A). If the effective inductance data already include the initial tolerance, do not multiply by 0.8 again.
The most accurate way to compare heating is to use the DC temperature-rise curves near 3.030 A. Use the typical (Typ.) values on the first page of the datasheet only for quick stage 1 screening. Before approving a part, always check its specific bias and temperature-rise curves and the corresponding test conditions. A lower profile does not guarantee that the existing pads will fit. Before assembly, compare the manufacturer’s recommended land pattern (pad width and spacing) and reflow profile, and check the EMI impact of any change in core or shielding construction.
For reference, the reflow limits specified in Bourns SRN6045 Rev. 01/20 p. 2 Soldering Profile are listed below (the SRP6060FA datasheet has no separate reflow table, so check it separately against the assembly process requirements).
| Stage / item (SRN6045 p. 2) | Allowable limit |
|---|---|
| Preheat Area | 150~200 °C / 60~120 sec |
| Max. Time Above 217 °C | 60~150 sec max |
| Peak Temperature | 250 °C max |
| Max. Peak Temperature −5 °C | 30 sec max |
After the part passes the datasheet comparison, use board measurements for final approval. Set pass criteria based on product requirements before testing, then check, in order: ① RMS current and steady-state temperature at normal load, ② peak current and protection behavior during startup, load transients, and overload, and ③ output ripple, loop response, and EMI. Review the 5 V output filter, compensation components, and PCB layout against actual design conditions rather than relying solely on the nominal values in the schematic.
In conclusion, even if you keep the original SRP6060FA-100M, the calculation at the nominal 350 kHz is not enough. At 255 kHz and 8 µH, ripple rises to 2.013 A p-p and peak current reaches 4.007 A, leaving no margin to the minimum current limit (4.0 A). Whether you keep the inductor or choose a replacement, the key is to set the allowable ripple first, then check that both peak current margin and heating meet the requirements at the lowest switching frequency.