Table of Contents
Side-by-side comparison at 5 V: B has higher capacitance, but hold off on ordering

This hypothetical design uses the TPS62130A to step down a 12 V input to 5 V. Keep the nominal output inductance at 1 µH and FSW set to Low, and replace only the single output MLCC, swapping A for B on the same 0805 footprint.
Start with the Typical effective capacitance at 5 V column, then check the last column to see whether the two values fall within the range TI evaluated for that LC combination.
| Role and part number | Rated voltage | Capacitance change at 5 V DC bias | Typical effective capacitance at 5 V | TI Table 9-2: comparison with the lower end of the evaluated range |
|---|---|---|---|---|
| Existing part A — C2012X5R1A226M125AB | 10 VDC | Approx. −68% | Approx. 7.0 µF | Below 11 µF |
| Candidate B — C2012X5R1V226M125AC | 35 VDC | Approx. −60% | Approx. 8.8 µF | Below 11 µF |
Table note: Both part numbers are 0805 (2.0 × 1.25 mm), with a nominal thickness of 1.25 mm, an X5R dielectric, and a nominal capacitance of 22 µF ±20%. The effective capacitance at 5 V is an estimate obtained by applying the percentage change from the TDK typical curve to the nominal value. 11–26.4 µF is the effective capacitance range TI considered for the nominal 1 µH and 22 µF combination.
Sources: TI TPS6213x datasheet, Rev. F, p. 14, Table 9-2 (1 µH row and 22 µF column), footnote (1), and FSW setting guidance. The TDK characteristic sheet for A and the TDK characteristic sheet for B each show the product specifications and the DC Bias Characteristic graph in the upper right on p. 1.
At 5 V, B has about 1.8 µF more capacitance than A. Even so, both fall short of 11 µF, the lower end of the evaluated range. Based on this comparison, hold off on placing a production order to replace A with a single B. By the same criterion, the existing part A also needs to be reevaluated. The next decision requires guaranteed effective capacitance data for B near 5 V that cover the actual operating range, or further verification under actual operating conditions.
How to read 7.0 µF and 8.8 µF from the TDK curves
The nominal 22 µF is a component specification. Effective capacitance is the capacitance available to the circuit when DC voltage is applied. This example uses the 5 V across the output capacitor. For more detail, see MLCC DC bias and effective capacitance basics.
Compare the two readings at 5 V in the graph below.

In the upper-right graph on p. 1 of each TDK characteristic sheet, find 5 V on the horizontal axis and read the percentage change on the vertical axis where that voltage intersects the curve. Multiply the nominal value by the fraction that remains to obtain the values in the table.
- A: Approx. 68% decrease → 32% remains, so
22 × 0.32→ approx. 7.0 µF - B: Approx. 60% decrease → 40% remains, so
22 × 0.40→ approx. 8.8 µF
Both values are estimates based on a like-for-like comparison of the typical curves for the two part numbers. They are not board measurements or guaranteed minimum values. For a 1-pass comparison of a replacement’s effective capacitance, reading the capacitance at the actual operating voltage from the curve for that part number is more direct than comparing voltage ratings.
In TI Table 9-2, what does 11 µF mean?
On p. 14 of the TI datasheet, follow the nominal 1 µH row in Table 9-2. The lowest capacitance column with a check mark is nominal 22 µF. TI directs users to set FSW to Low when using 1 µH and evaluated the stability of the checked LC combinations through simulation and lab testing.
The table below reproduces only the nominal inductor row for 1 µH and the 4.7–22 µF columns from Table 9-2 on p. 14 of the TI datasheet.
| Nominal output inductor | Nominal 4.7 µF | Nominal 10 µF | Nominal 22 µF |
|---|---|---|---|
| 1 µH | No check mark | No check mark | Check mark |
View the original table and footnotes
Footnote (1) explains that an effective capacitance variation of −50%/+20% was considered. Applied to the nominal 22 µF, this gives a lower end of 22 × 0.50 = 11 µF and an upper end of 22 × 1.20 = 26.4 µF. The low-ESR, nominal 22 µF X5R or X7R ceramic capacitor recommended on p. 15 of the datasheet is a starting point for component selection, while 11–26.4 µF is the effective capacitance range considered for that combination in the table. The values from the TDK curves, approximately 7.0 µF and approximately 8.8 µF, are part-specific estimates to compare against that range.
Therefore, 11 µF is neither an absolute minimum rating for the TPS62130A nor the threshold at which instability begins. The check marks in the TI table apply to LC combinations, not individual part numbers. When typical values fall outside the range, as they do for A and B, the combination must be verified separately under actual operating conditions.
What to check before lifting the order hold
First, ask TDK for guaranteed effective capacitance data for B near 5 V that cover the actual output voltage and temperature ranges. The goal is to establish a lower bound that accounts for tolerance, temperature, aging, and unit-to-unit and lot-to-lot variation. Rather than simply multiplying the typical curve values by nominal tolerance, temperature, and aging factors, check the guarantee conditions that apply to the operating range.
TDK’s guide to measuring the capacitance of high-capacitance MLCCs specifies the AC voltage and frequency to set on the instrument for each capacitance range. Table 1 — Capacitance measurement conditions according to TDK’s general specifications is excerpted below to show the row that applies to the two nominal 22 µF parts discussed here.
| Nominal capacitance range | Instrument AC measurement voltage | Measurement frequency |
|---|---|---|
| Above 10 µF (includes the 22 µF parts discussed here) | 0.5 ± 0.2 Vrms | 120 Hz ± 10% |
This table gives general measurement conditions for checking nominal capacitance. The 5 V used in the earlier comparison is the DC bias actually applied at the output. The characteristic sheets for the two part numbers do not specify the individual AC measurement conditions used to obtain the DC bias curves.
If the guaranteed data alone are not enough to make a decision, verify in two steps:
- Component comparison: Use an instrument that can apply DC bias to compare A and B under the same conditions. Record the applied DC voltage, temperature, measurement frequency, and actual AC amplitude across the component terminals.
- Board verification: Define the design’s input voltage, load, and temperature ranges, along with the load step and slew rate. Set the allowable output deviation and recovery time in advance, then check the actual board’s load transient response against those criteria.
Comparing samples shows which component retains more capacitance under the same conditions. Board verification checks whether the board meets the specified output deviation and recovery time criteria with a single instance of that component installed. Keep those two questions separate when deciding whether to place the order.
Leave a Reply